E6581381
F-54
6
■
How to set parameters
a) Operating method: Terminal input
Set the operation control mode selection
EOQF
to
.
b) Use the RES terminal for switching. (Instead, other terminals may be used.)
RES: Acceleration/deceleration switching signal
Title
Function
Adjustment range
Setting value
H
Input terminal selection 3 (RES)
0-71
5 (the second
acceleration/deceleration
mode selection)
■
Acceleration/ deceleration pattern
Acceleration/deceleration patterns can be selected individually, using the acceleration/deceleration 1, 2
and 3 parameters.
1) Linear acceleration/deceleration
2) S-pattern acceleration/deceleration 1
3) S-pattern acceleration/deceleration 2
Title
Function
Adjustment range
Default setting
H
Acceleration/ deceleration 1 pattern
0
H
Acceleration/ deceleration 2 pattern
0: Linear
1: S-pattern 1
2: S-pattern 2
0
+
Both the settings of the S-pattern lower-limit and upper-limit adjustment parameters (
H
and
H
) are applied to any acceleration/deceleration S-pattern.
⇒
For an explanation of acceleration/deceleration patterns, see section 6.16.1.
6.17 Protection functions
6.17.1 Setting motor electronic thermal protection
VJT
: Motor electronic thermal protection level 1
H
: Motor electronic thermal protection level 2
H
: Motor 150%-overload time limit
H
: Motor electronic-thermal protection retention selection
Summary of Contents for TOSVERT VF-FS1 Series
Page 2: ......
Page 15: ...E6581381 A 3 1 1 3 Names and functions 1 3 1 Outside view Operation panel ...
Page 18: ...E6581381 A 6 1 VFFS1 2004 2037PM VFFS1 4004 4055PL Note EMC plate is supplied as standard ...
Page 36: ......
Page 40: ...E6581381 B 4 2 2 2 2 Standard connection diagram 2 ...
Page 54: ......
Page 56: ...E6581381 D 2 4 4 1 Flow of status monitor mode Flow of monitor as following ...
Page 66: ......
Page 180: ......
Page 196: ......
Page 208: ......
Page 233: ...E6581381 L 5 12 Outline drawing Fig A Fig B Fig C Fig D ...
Page 242: ......
Page 248: ......
Page 251: ......