e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
REMOTE SERVICE
10 - 28
Fig.10-30
Key in the time (acceptable values: 00:00-23:59) in “Time”.
Key in the time in the hour column of “Time”, press the scroll button, key in the time in the minute
column of “Time”.
After all the settings are completed, press the [OK] button. The display returns to the screen in
step (5).
(7)
Press the [OK] button. The setting completes.
Notes:
Service Notification setting is also available from the following setting mode (08).
Items
08 code
Contents
Service Notification setting
9793
0: OFF (Invalid) 1:E-mail 2:FAX
E-mail address 1
9794
Maximum 192 letters
E-mail address 2
9607
Maximum 192 letters
E-mail address 3
9608
Maximum 192 letters
FAX number
9784
Maximum 32 digits
Total Counter Transmit setting
9795
0: OFF (Invalid) 1: ON (Valid)
Total counter transmission date
setting
9796
0 to 31
Total counter transmission date
setting(2)
9880
0 to 31
Day of total counter data
transmission
9881
1 byte
00000000(0)-01111111(127)
From the 2nd bit - Sunday, Monday,
Tuesday, Wednesday, Thursday, Friday,
Saturday
Total counter transmission interval
setting
(Hour/Hour/Minute/Minute)
9606
00:00-23:59
Service Call Transmit setting
9605
0: OFF (Invalid) 1: ON (Valid)
PM Counter Transmit setting
9797
0: OFF (Invalid) 1: ON (Valid)