6
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2555C/3055C/3555C/4555C/5055C
SETTING / ADJUSTMENT
6 - 53
*
If the code 8008 is performed, the adjustment will be applied to all paper types.
1200dpi
*
If the code 8009 is performed, the adjustment will be applied to all paper types.
(5)
When the adjustment has finished normally, press the [OK] button to have the adjustment results
reflected.
(To cancel the reflection of adjustment results, press the [CANCEL] button.)
In the case of an abnormal ending, “ADJUSTMENT ERROR” is shown. Press the [CANCEL]
button to clear the error display.
When it is cleared, the control panel display will return to the ready state. Then, check if the patch
chart on the original glass is placed in the wrong direction or if it is placed inclined on the original
glass, and then repeat step (3) and afterward.
To select the paper type for the automatic gamma adjustment in user calibration, change the code
below to "1". (copy/print)
Code
Paper type
Remarks
8005-0
Plain paper
When the reproduction of gradation is not
appropriate, the gradation reproducibility of all colors
Y, M, C and K can be corrected by performing this
automatic gamma adjustment.
8005-2
Recycled paper
8005-3
Thick paper 1
8005-4
Thick paper 2
8005-5
Thick paper 3
8005-6
Thick paper 4
8005-7
Special paper 1
8005-8
Special paper 2
8005-9
Special paper 3
8005-10
Thin paper
8009
All paper types
Code
Remarks
08-9059
0: No paper selecting buttons displayed
1: Paper selecting buttons displayed. (For both Copy and Printer)