e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 146
8.3.19
Circuit related service call
[C5A0] EEPROM not connected (LGC board)
[C5A1] EEPROM data abnormality (LGC board)
[C900] Connection error between the SYS board and the LGC board
Classification
Contents
Circuit related service call
SRAM board data abnormality (LGC board)
Check item
Measure
EEPROM
EEPROM check
LGC board
•
IC socket check (IC52)
•
Board check
Replacement part
Measure
EEPROM
LGC board
Classification
Contents
Circuit related service call
SRAM board data abnormality (LGC board)
Check item
Measure
EEPROM
EEPROM check
LGC board
•
IC socket check (IC52)
•
Board check
Replacement part
Measure
EEPROM
LGC board
Classification
Contents
Circuit related service call
Connection error between SYS board and LGC board
Check item
Measure
LGC board
•
Connector check (CN350)
•
Board check
SYS board
•
Connector check (CN128)
•
Board check
Replacement part
Measure
LGC board
SYS board