e-STUDIO2555C/3055C/3555C/4555C/5055C
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
ERROR CODE AND TROUBLESHOOTING
8 - 238
[F902_4] SYS board model information error
Classification
Error item
Other service call
Invalid SYS board is installed to the equipment.
Check item
Measures
SYS board
Check if the model of the equipment matches the color of the
label on the SYS board.
<Color of label>
•
25/30/35ppm: Yellow or pink
•
45/50ppm: Blue or brown
Fig.8-1
Setting
1. Install the system firmware.
2. If the error cannot be solved after installing the system
firmware, reinstall the system software and application
program.
P. 11-21 "11.3.2 Update procedure"([A]Updating firmware)
Label