05/08
Mode
Element
Sub
element
Item
Subitem
Code
Sub-
code
Details
Default
value
Acceptable
value
RAM
Contents
Proce
dure
Servic
e UI
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
1
Recommended
number of output
pages for
replacement
Refer to
contents
8 digits
M
<Default value>
30ppm: 540000
35ppm: 630000
45ppm: 680400
50ppm: 756000
25ppm: 450000
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
2
Number of output
pages at the last
replacement
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
3
Present driving counts
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
4
Recommended
driving counts to be
replaced
2E+06
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
5
Driving counts at the
last replacement
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
6
Present output pages
for control
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
7
Present driving counts
for control
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6316
8
Number of times
replaced
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer Y roller
6317
Date of previous
replacement
0
8 digits
M
2
08
Setting
mode
Counter
PM
counter
1st transfer M roller
6318
0
Present number of
output pages
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer M roller
6318
1
Recommended
number of output
pages for
replacement
Refer to
contents
8 digits
M
<Default value>
30ppm: 540000
35ppm: 630000
45ppm: 680400
50ppm: 756000
25ppm: 450000
4
08
Setting
mode
Counter
PM
counter
1st transfer M roller
6318
2
Number of output
pages at the last
replacement
0
8 digits
M
4
08
Setting
mode
Counter
PM
counter
1st transfer M roller
6318
3
Present driving counts
0
8 digits
M
4