ERROR CODE AND TROUBLESHOOTING
8 - 290
8.5.8
Blurred image
Fig.8-12
Cause/Section
Step
Check item
Measures
Scanner
1
Is the scanner bedewed?
Clean it.
Drum
2
Is the drum bedewed or dirty?
Wipe the drum with dry cloth.
*
Be sure never use alcohol or
other organic solvents because
they have bad effect on the drum.
Ozone
exhaust
3
Is the ozone exhaust fan operating
properly?
Check the connection of the
connector.
4
Is the ozone filter stained or
damaged?
Replace it.
LED head
5
Is there foreign matter or dust on the
LED head?
Clean the LED head.
Main charger
6
Is the charger grid dirty or deformed? Clean or replace the charger grid.
Main charger
7
Is there foreign matter on the
charger grid?
Remove foreign matter.
Clean or replace the charger grid.
Feeding direction