ERROR CODE AND TROUBLESHOOTING
8 - 319
8.5.26
Uneven light distribution
Fig.8-31
Cause/Section
Step
Check item
Measures
Original glass
1
Is the original glass dirty?
Clean the glass.
Main charger
2
Are the needle electrode, grid and
case dirty?
Clean or replace them.
Discharge
LED
3
Is the discharge LED dirty?
Clean it.
Scanner
exposure
lamp
4
Are the reflector, exposure lamp,
mirrors, lens, etc. dirty?
Clean them.
5
Is the exposure lamp tilted?
Adjust the installed position of the
lamp.
6
Is the lamp discolored or degraded?
Replace it.
Feeding direction