8
© 2012-2013 TOSHIBA TEC CORPORATION All rights reserved
e-STUDIO2555C/3055C/3555C/4555C/5055C
ERROR CODE AND TROUBLESHOOTING
8 - 167
MJ-1036
[CB80] Backup RAM data abnormality
MJ-1107/1108
[CB81] Flash ROM abnormality
MJ-1107/1108
Classification
Contents
Finisher related service call
Backup RAM data abnormality: Abnormality of checksum value
on finisher controller PC board is detected when the power is
turned ON.
Error
Timing of detection
EEPROM
Data readout check is performed after data writing and the
result of the data readout check does not conform to the written
data.
The equipment does not enter the ready status after the
specified time has passed from data writing.
Probable cause
Checking and measures
Finisher control PC board (FIN)
abnormalit
Replace the finisher control PC board (FIN) as the cause is a
fault in the IC of the backup RAM.
Classification
Contents
Finisher related service call
Backup RAM data abnormality: Abnormality of checksum value
on finisher controller PC board is detected when the power is
turned ON.
Check Item
Measure
Main power switch
Turn OFF the main power switch, then back ON.
Replacement part
Measure
Finisher controller PC board
Classification
Contents
Finisher related service call
Flash ROM abnormality: Abnormality of checksum value on
finisher controller PC board is detected when the power is
turned ON.
Check Item
Measure
Main power switch
Turn OFF the main power switch, then back ON.
Finisher controller PC board
Board check
Replacement part
Measure
Finisher controller PC board
Summary of Contents for e-studio 2555c
Page 6: ......
Page 10: ......
Page 1550: ......
Page 1557: ......
Page 1558: ...1 11 1 OSAKI SHINAGAWA KU TOKYO 141 8562 JAPAN ...