Abnormality detection by the thermistors
The following table shows the conditions for judging the temperature abnormality of the fuser belt, and
the detecting timing.
Check timing
Error code
Counter
Center
Edge
Error
judging
timing
Power ON
C449
9 Fixed
220°C or above
235°C or above
When pre-
running end
temperature
or ready
temperature
is detected
C449
22 Fixed
220°C or above
235°C or above
On usual
C445
5 Not fixed
Ready temperature
or above
-
C446
6 Fixed
During ready
C449
23 Fixed
220°C or above
235°C or above
On usual
C447
7 Fixed
0°C or below
-
C447
63 Fixed
-
0°C or below
During
printing
C449
25 Fixed
220°C or above
235°C or above
On usual
C447
24 Fixed
0°C or below
-
C447
64 Fixed
-
0°C or below
C447
65 Fixed
40°C or below
-
C447
66 Fixed
-
40°C or below
At energy
saving mode
C449
27 Fixed
220°C or above
235°C or above
On usual
At paper jam
C449
29 Fixed
220°C or above
235°C or above
On usual