System Configuration Setup
Disk array (RAID) settings
113
The following events may occur if the system load increases significantly:
❖
Event ID: 9
Source:mraid35x
(Explanation) Device SCSI Port did not reply within the time-out.
- Displayed at the "Application Log" of the NT Event Viewer
If the above messages appear, reduce the load by pressing the
Enter
key, and then
restarting Power Console.
Automatic rebuilding with a hot spare
If the server is configured with a hot spare (standby disk), you can rebuild the disk array
using the hot spare, even if a hard disk drive (other than the hot spare) is malfunctioning.
When the rebuild completes, the status indicators on that hard disk drive will turn off. To
ensure that the fault alarm operates properly, set Alarm Control to “Enabled.”
Rebuilding the disk array using Power Console Plus
When rebuilding the server’s disk array, the following error may occur when you start
Power Console:
If this error message appears on screen, press the
Enter
key before restarting the
rebuilding process.
No Me
gaRAID Adapter card found!
[OK]
!!!Error on starting device!!!
[OK]