Getting Started
Isolating EPS-R cage and cooling fan unit failures
34
Isolating EPS-R cage and cooling fan unit failures
To regulate the temperature inside the server, the Toshiba Magnia 3200 is equipped with:
❖
Intake fan module(s) - For redundancy, up to two intake fan modules can be installed
in tandem in the fan bays located in the forward lower section of the server chassis.
❖
Exhaust fan module(s) - The exhaust fan module (duct) contains a single fan, but can
be fitted with an additional exhaust fan module for redundancy.
❖
EPS/EPS-R cooling fans - Server models with an EPS power supply unit have a
single integrated cooling fan to regulate the temperature of the unit. In EPS-R
models, the power supply units are housed in the EPS-R cage. The EPS-R cage is
configured with two integrated cooling fans for redundancy. If a fan fails, the remaining
fan will continue to cool the power supply unit(s) installed in the cage.
Location of system cooling fans
Exhaust fan module
Redundant
exhaust fan
(Installed in
the fan duct)
Additional
air-intake fan
module
Primary
exhaust fan
(Installed in
the fan duct)
Standard air-intake fan
module