Connecting Hardware Devices
CPU module
71
Installing a CPU module
1
If the server is in operation, shut it down. Then remove the access panel. For
detailed instructions, read steps 1 through 5 in
Maintenance overview
on page 53.
2
Remove the exhaust fan module. For instructions, see
Removing and replacing the
redundant exhaust fan
on page 63.
3
Raise the lock lever on the CPU socket.
Raise the lock lever
WARNING: Never disassemble the server beyond what is described in this manual.
Failure to observe this precaution could result in electric shock, cause a system
fault, or void your warranty.
Never install or remove CPU modules immediately after turning off the server. To
avoid burn injuries, wait for the heat around the CPU modules to dissipate.
CAUTION: Installing a CPU module while the server is on could cause damage to
the server or the CPU module.
CPU modules can be seriously damaged by static electricity. Wear a wrist or heel
ground cable to discharge static electricity carried on your body. If such equipment
is not available, touch a grounded metal object to discharge static electricity before
working with sensitive electronic components.