Connecting Hardware Devices
SCSI devices
77
Terminating SCSI devices
The internal SCSI bus is terminated at the SCSI controller and at the end of the SCSI
cable or the SCSI backplane. Set the terminator of the SCSI devices you install to
disabled.
Removing device bay spacers
Device bay spacers are used to keep dust and dirt out of the server.
1
If the server is in operation, shut it down. Then remove the access panel.
For detailed instructions, read steps 1 through 5 in
Maintenance overview
on page
53.
2
Press the rail latches inward, then remove the spacer from the device bay.
Removing the device bay spacer
3
Remove the rails attached to the device bay spacer. You will need these rails to
install a SCSI device in the 5.25-inch device bay.
Installing SCSI devices
Use only SCSI devices recommended by Toshiba. Other devices may be the wrong size
and shape to fit in the device bay, or they may cause unstable operation or other
problems. Toshiba assumes no responsibility for devices not specifically recommended.
1
If the server is in operation, shut it down. Then remove the access panel. For
detailed instructions, read steps 1 through 5 in
Maintenance overview
on page 53.
HINT: Store the device bay spacer for possible future use.