Hardware Diagnostics
HW Diagnostics Program Main Menu
126
Meaning of Details Information (DETAILS = XXXXXXXXXXXXXXXX)
❖
07. NPX TEST checks the computer's floating data processing unit functions.
NPX TEST (NPX) Error Log
83
MEDIUM ERROR
Error occurred because of the
failure of a medium
84
HARDWARE ERROR
Hard error that is impossible to
recover occurred during command
execution
85
ILLEGAL REQUEST
CBD is illegal
86
UNIT ATTENTION
Function of hard disk drive has
been changed
87
DATA PROTECT
Data protection error
89
VENDOR UNIQUE
Unique error of disk maker
8A
COPY ABORTED
COPY command stopped
8B
ABORTED COMMAND
Execution of a command is
correctly stopped
8C
EQUAL
Comparing result of the search
data command is satisfied
8E
MIS COMPARE
Comparing command error
E0
STATUS ERROR
Status error
F0
NO DRIVE ERROR
Target drive has not been found
FE
NO DRIVE ERROR
Target drive has not been found
FF
DATA COMPARE ERROR
Data comparing error
Details
Meaning
AA
Host number that the hard disk drive is connected,
and channel number
BB
Driver completion status
CC
ASPI status
DD
Host status
EEEE
Sense data
FFFF
Sense code
Status
Error name
Meaning
01
NO CO-PROCESSOR
Co-processor recognition error
02
CONTROL WORD ERROR
Set control word error
03
STATUS WORD ERROR
Status word error
04
BUS ERROR
BUS error
05
ADDITION ERROR
Addition test error
06
MULTIPLICATION ERROR
Multiplication test error
07
XCEPTION ERROR
Exception error