Initializing the Micro-Tech
Acquiring Basic System Data
2-4
Micro-Tech 9101/9201 Reference Manual, Rev J
Thermo Fisher Scientific
(* Also known as a lever-ratio, pivot point, or trunion scale.)
Here is a list of belt-scale codes for non-pivoting scales. (For a complete
list of belt-scale codes, see
Non-pivoting belt-scale codes*: 43–53, 60, 214, 215.
(* Please note that this is not an exhaustive list, because newer or
custom scales are not listed.)
We suggest you print or photocopy this page and insert the required data
into the table below. Doing so will save you considerable time when you
come to initialize the Micro-Tech software.
Table 2–1.
Initialization Data Sheet (Non-Pivoting)
Parameter
*
Details of Your
Particular System
Defaults from
Table A–1, or other
Number of weigh idlers
4
Number of load cells
4
Idler spacing (inches)
48
Conveyor angle (degrees)
0
Load-cell capacity (lbs.)
250
Load-cell sensitivity (mV/V)
3.0
Load-cell resistance #1 thru #4 (ohms)
350
Belt length (feet)
—
Time for one belt revolution (seconds)
—
Number of revolutions for test
>3
Time to complete test revolutions (seconds)
—
* The example above, including the defaults, is for belt-scale code 49. Your weighing
system will, most likely, have a slightly
different
list of required parameters and defaults.
NOTE.
For more information about the parameters listed above, please
see pages 2-5 through 2-10.
Non-Pivoting
Scales
Summary of Contents for Micro-Tech 9101
Page 1: ...Micro Tech 9101 9201 Integrator Reference Manual REC 4281 Rev J Part Number 127336 English...
Page 82: ......
Page 118: ......
Page 124: ...A 2 Micro Tech 9101 9201 Reference Manual Rev J Thermo Fisher Scientific...
Page 172: ......
Page 234: ......
Page 315: ......
Page 316: ......
Page 317: ......
Page 318: ......
Page 319: ......
Page 320: ......
Page 321: ......
Page 322: ......
Page 323: ......
Page 324: ......
Page 325: ......
Page 326: ......
Page 327: ......
Page 328: ......
Page 329: ......