Thermo Fisher Scientific
Micro-Tech 9101/9201 Reference Manual, Rev J
C-45
Example 6: The Host Sends the Batch Setpoint to the Micro-Tech
Batch setpoint = 200.5 Tons
Address of Slave = 01
Address of Host = 02+
Host (PLC)
Slave (Micro-Tech)
10H
→
01H
01H
10H
02H
01H
02H
0FH
00H
00H
00H
67H
00H
00H
01H
00H
07H
00H
08H
07H
99H
09H
06H
94H
08H
00H
80H
48H
43H