98
Adding shared storage and testing disks for SCSI-3 compliance
About adding shared storage
About adding shared storage
This section describes how to set up a system with SCSI-3 protection for shared
storage.
If two or more systems in the Policy Master cluster share storage devices, you
can configure and use the I/O fencing feature in VCS One. In the event of a
network failure, I/O fencing protects the shared storage from data corruption.
Requirements for adding shared storage
To meet the requirements for shared storage in a production environment, you
must supply the following:
■
Three coordinator disks that support SCSI-3 persistent reservations. This is
a requirement for I/O fencing, and applies only to the Policy Master. Clients
do not require coordinator disks.
■
Two switches for I/O connection redundancy.
Adding storage devices
For the Policy Master in a production environment, you need to add a minimum
of three coordinator disks in addition to the storage for data. This requirement
does not apply for clients.
To add storage devices to the VCS One cluster
1
Physically connect each storage device to each system in the Policy Master
cluster.
2
On each system in the VCS One cluster, scan the drives, update the Veritas
Volume Manager (VxVM) device list, and reconfigure VxVM DMP with the
new devices with the following command:
vxdisk scandisks
3
On one system in the VCS One cluster, initialize the disks with the following
command:
vxdiskadm
4
Choose
1 Add or initialize one or more disks
from the menu.
5
At the prompt, to select devices, type
list
.
6
Type the name of the devices you are adding when prompted to select
devices. Do one of the following:
■
For Solaris or AIX, enter the following:
c3t1d0 c3t2d0
Summary of Contents for Veritas Cluster Server One
Page 1: ...Veritas Cluster Server One Installation Guide AIX HP UX Linux Solaris 5 0...
Page 3: ...Symantec Corporation 350 Ellis Street Mountain View CA 94043 http www symantec com...
Page 16: ...16 Contents...
Page 34: ...34 Getting ready to install VCS One Configuring ssh rsh or remsh before installing...
Page 82: ...82 Installing the Simulator Installing the Simulator...
Page 126: ...126 Upgrading from VCS One 2 0 1 to 5 0 Upgrading the client...
Page 148: ...148 Sample Policy Master upgrade scenarios Upgrade scenario details...
Page 194: ...194 Sample installation output Installing the VCS One client...
Page 210: ...210 Index...