100
Adding shared storage and testing disks for SCSI-3 compliance
Setting up and testing data disks
Setting up and testing data disks
Verify that each disk you added for use as a data disk supports SCSI-3 persistent
reservations and I/O fencing. Use the
vxfentsthdw
utility to verify that the
storage you added supports SCSI-3 persistent reservations. The procedure may
destroy data on the disk.
Note:
If the disks you want to test have data on them that you want to preserve,
use the -r (read-only) option of vxfentsthdw. Be advised that, with the -r option,
not all SCSI-3 compliance tests are run.
When you run the utility, you are prompted for:
■
The names of two systems connected to the storage disks.
■
The name of the disk as it is displayed on each system. A given disk may
have a different name on each system.
To test data disks using vxfentsthdw
1
Make sure the two systems are connected to the storage device you are
testing, and that the systems are running the same operating system.
2
Ensure that both systems have mutual connectivity via rsh or ssh
communications.
3
Start
vxfentsthdw
. Enter the following. If you are using ssh, omit the
-n
option:
/opt/VRTSvcsone/vxfen/bin/vxfentsthdw -n
4
At the prompts, provide the required information. If the test succeeds, the
following information is displayed:
The disk /dev/
disk_name
is ready to be configured for I/O
Fencing on node
name_of_first_node
The disk /dev/
disk_name
is ready to be configured for I/O
Fencing on node
name_of_second_node
If the testing does not display a message that the disk is ready to be
configured for I/O fencing, the disk has failed the testing.
5
Repeat this test on all shared data disks connected to the system.
Summary of Contents for Veritas Cluster Server One
Page 1: ...Veritas Cluster Server One Installation Guide AIX HP UX Linux Solaris 5 0...
Page 3: ...Symantec Corporation 350 Ellis Street Mountain View CA 94043 http www symantec com...
Page 16: ...16 Contents...
Page 34: ...34 Getting ready to install VCS One Configuring ssh rsh or remsh before installing...
Page 82: ...82 Installing the Simulator Installing the Simulator...
Page 126: ...126 Upgrading from VCS One 2 0 1 to 5 0 Upgrading the client...
Page 148: ...148 Sample Policy Master upgrade scenarios Upgrade scenario details...
Page 194: ...194 Sample installation output Installing the VCS One client...
Page 210: ...210 Index...