Rear of riser card assembly with slots 1-5
29.
Replace the riser card assembly into the rear of the NetBackup 5220.
30.
Align the three hooks in the PCI riser assembly with the matching slots at the back
of the chassis.
31.
Press down evenly until the three hooks on the rear of the PCI riser assembly
engage the chassis rear panel slots.
32.
Be sure that riser assembly fits securely into the equivalent sockets on the
mainboard.
33.
Connect any cables to the newly installed PCI add-in card as needed.
34.
Replace the chassis cover at top rear of the NetBackup 5220 enclosure.
35.
Slide the cover from the rear of the device towards the front.
Carefully line up both sides of the cover with the sides of the chassis itself. Do not
allow warping or damage to the cover.
36.
Reinstall the single screw at the right front of the external chassis.
37.
Reinstall the NetBackup 5220 into the rack.
38.
Connect peripheral cables and the two main AC power cables.
39.
Turn on power to the device to restart.