Fan failure
If alarms in the monitoring systems indicate fan problems or high temperatures at
the air intake vent, make sure room air cooling is adequate.
TBD more info
Temperature abnormality
Several problems may lead to high (great than 35C) temperatures of the device.
Thoroughly check all aspects of the rack environment.
Make sure no other equipment are overly warm and close to the devices.
Make sure room temperature is within specifications.
Make sure AC power to the device is correct.
When the system alarm/location indicator is on and red, the alarm information is
displayed on the ISM monitoring interface.
Alarm information
Classification
Type
Device
Description
Overtemperature of
the CPU core
Temperature
CPU
Temperature is not
critical yet but is
approaching the upper
limit of the range.
Overtemperature of
the air intake of the
chassis
Temperature
Chassis air
intakc
Temperature is not
critical yet but is
approaching the upper
limit of the range.
Fan module absence
Cooling device
Fan
Device absent
Investigate other possible problems
1.
Make sure the front and back of the NetBackup 5220 are clear of any
obstructions so that air can flow easily from front to back.
2.
Verify that room temperature is within specifications.
3.
Verify that any equipment near the device is at normal temperature.
4.
If high temperatures or alarms persists, contact technical support.