Error messages through the command line system
GUI showing the command on the TBDInterface
Depending on the nature of the failure, the failed drive might not appear in
the CLI, or the failed drive might display errors when you run the enclosure
command or the link command.
To view link status:
At the cli> prompt, type
link
and press Enter.
cli>link
Link Statistics display after Link Status. A separate command is not required.
To clear all link error counts:
At the cli> prompt, type
link -a clear
and press Enter.
cli>link -a clear
Q: Can I hot-swap a failed drive with a new drive?
A: Yes. Disk drives are hot-swappable on the Symantec Storage Shelf.
Q: Can the Symantec Storage Shelf run using just one power supply?
A: Yes, it is possible to run the Symantec Storage Shelf on a single power
supply. However, leaving one power supply off means there is no redundancy
if the other power supply fails. Also, omitting one power supply and its fans
reduces air flow through the enclosure, which can contribute to overheating.
Always switch on both power supplies.