Chapter 6
NetBackup 5220 hardware removal and replacement
125
has been installed into the NetBackup 5220 Riser Card Assembly upon receipt of
shipment.
If a Symantec Storage Shelf is ordered later than the NetBackup 5220, a RAID
Controller Card and accessories will need to be ordered and installed separately.
If the RAID card and its accessories are required but not installed, obtain the
necessary items from the customer and install them into the NetBackup 5220 chassis
per the following procedure.
1.
Shutdown the NetBackup 5220 and any peripherals.
Be sure that all devices are off and no programs are running. If you disconnect
devices while programs are running, data loss may occur.
2.
Disconnect the main AC power cord and peripheral cables/cords from the rear
of the NetBackup 5220.
3.
Wear ESD preventive wrist straps.
4.
Carefully remove the NetBackup 5220 from the rack cabinet.
5.
Place it on a grounded, ESD protective surface.
6.
Remove the screw on the top, right-hand side of the chassis. Use the thumb
grip on the top, left-hand side of the chassis to slide the cover towards the rear
of the device.