NICE3000 User Manual Preface
9
Standard Function
Serial
number
Function name
Function introduction
Remark
49
Car arrival gong
After the elevator arrival at the destination floor in
accordance with the requirements of passengers, the
car top board sent the signal.
Standard
Settings
50
Outside
approaching gong
After the elevator reach the floor
,
through MCTC-
HCB-B sent outside lights arrival forecasting
Configure
MCTC-
HCB-B
51
Outside arrival
gong
After the elevator reach the floor
,
through MCTC-
HCB-B sent outside clock
arrival forecasting
Configure
MCTC-
HCB-B
52
Double hall call in
the same floor
Double hall-call can be set when opposite door in the
same floor
Function
Selection
53
Forced
deceleration
monitoring function
System in automatic operation mode correcting the
location of the elevator car according to the forced
deceleration switch position , as well as the action
switches to monitor the situation
Standard
Settings
54
Call conglutination
judgment
System can identify the conglutination situation of the
hall call button, automatically remove the call of the
adhesion to avoid the elevator can not be closed to
run caused by the hall-call button conglutination
Function
Selection
55
Weighing signal
compensation
in high-end applications System can use weighing
signal to compensate the start of the elevator
Function
Selection
56
Leveling fine-
tuning
system can be fine-tune the accuracy of leveling by
adjust the f4-00 parameter
Standard
Settings
57
Next landing
If the elevator continued to open the door more than
the time of open the door, the open limit has not yet
been act, the elevator would be turned into the closing
door state, and after the door closed, automatically run
the next registered floor
Standard
Settings
58
Fault record
System recorded 11 faults, including fault resulting
from information such as time and floors.
Standard
Settings
59
Short-circuit test
against the earth
When first supply power, the system test output U, V,
W to determine whether the existence of short-circuit
fault.
Standard
Settings
60
Overload
Protection
When the lift when the load over the rated load;
elevator alarm, stop the run.
Standard
Settings
61
Light curtain
protection
When something block in the middle of the door during
the door is closing, the light curtain protection action
then the elevator turn to open the door. But the light
curtain protection does not work in the fire operation.
Standard
Settings
62
Non-open outside
door zone
Prohibit open the door automatically when system not
in gate-area
Standard
Settings
63
Protection against
reversal travel
System identify the direction of rotary encoder
feedback signals
,
determining the actual direction of
the motor in operation
,
once the signal reversed the
system will be alarm
Standard
Settings
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...