Function parameter description NICE3000 User Manual
136
Those parameters mentioned above are the interior time of NICE3000.This clock can count
time when there
’
s power failure.Nice3000 can complete many special functions with time by
this clock such as fastigium service, etc. So users should set this parameter right by actual time
when first electrify.
Function code
Name
Setting Range
Default
Min. Unit
F9-09
Accumulative working
time
0
~
65535h
0
1
F9-11
RUN times high bit
0
~
9999
1
1
F9-12
RUN times low bit
0
~
9999
0
1
They are total accumulative actual lift working time and running times. These function
parameters are read only and user isn
’
t allowed to amend them. Lift accumulative run times =
run times high bit
×
10000 + run times low bit.
6.11 FA Group Keyboard Setting Parameters
FA-00
Small keyboard display selection
Default
0
Min. Unit
1
Setting Range
0
:
Reversal display, physics floor
1
:
Positive display, physics floor
2
:
Reversal display, external call data
3
:
Positive display, external call data
There are 3 bit LED displays at NICE3000 main control panel. User can change its display
direction by changing this function code; thereby it
’
s convenient to control the design of the
cabinet. No matter how to fix the main control panel, you can look through it easily. When
the setting is 0 or 1, small keyboard displaying data is the number of physics floor .When the
setting is 2 or 3,small keyboard displaying data is external call data.
FA-01
Run display 1
Default
65535
Min. Unit
1
Setting Range
0
~
65535
This function code is made up of a binary number with 16 emic that display 16 kinds of running
state parameters. Each parameter is controlled by one binary number,
”
1
”
expresses that
display this parameter,
”
0
”
expresses that don
’
t display this parameter. If want to display
parameter as the following list, relevant binary number should be set as follows:
Binary bit Parameter Display or
not
Binary bit
setting
Binary bit Parameter Display or
not
Binary bit
setting
Bit0
Running
speed
Display
1
Bit8
Output
terminal
Not
display
0
Bit1
Rated
speed
Display
1
Bit9
Currently
floor
Not
display
0
Bit2
Bus
voltage
Display
1
Bit10
Currently
station
Not
display
0
Bit3
Output
voltage
Not
display
0
Bit11
Car load
Display
1
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...