Function parameter description NICE3000 User Manual
148
FE-32
Lift factory function selection1
Default
35843
Min. Unit
1
Setting Range
0
~
65535
This function code sets the lift factory required function. Each function is controlled by one
binary number,
”
1
”
expresses this function allowable,
”
0
”
expresses this function forbidden.
If lift needs motorman function, fire return function, inspection automatic close, car call miss-
delete, door lock jump-out inspection function valid while other function invalidation, the binary
system setting is as follows:
Binary bit
Function
Binary setting
Binary bit
Function
Binary setting
Bit0
Motorman
1
Bit8
Time-sharing
service floor
0
Bit1
Fire return to
main floor
1
Bit9
Independent
running
0
Bit2
Re-leveling
0
Bit10
Inspection
automatic
close door
1
Bit3
Pre-opening
0
Bit11
Car call miss
delete
1
Bit4
Hall call
conglutination
disposal
0
Bit12
Hall call miss
delete
0
Bit5
Night security
floor
0
Bit13
Emergency
auto-running
car
0
Bit6
Down
collective
selective
fastigium
service
0
Bit14
Emergency
auto-rescue
overtime
protection
0
Bit7
Fastigium
service
0
Bit15
Door lock
jump-out test
1
The setting binary number is 1000110000000011; the corresponding algorism number is 35843,
so FA-01 should be set as35843.
FE-33
Lift factory function selection2
Default
32
Min. Unit
1
Setting Range
0
~
65535
Factory default is forced reducer conglutination inspection function, which is listed in the
following chart.
Binary bit
Function
Binary setting
Binary bit
Function
Binary setting
Bit0
Reserved
1
Bit8
N.C. output of
enclosed star
contactor
0
Bit1
Door opening
limit keep open
1
Bit9
Reversal leveling
immediate stopping
0
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...