Structure of the control system and the component introduction NICE3000 User Manual
54
Instruction of buttons on the operation panel keyboard:
4)
key
name
function
PRG
Program key
Enter or exit the primary menu and delete quick menu
ENTER
Confirm
Enter the menu level by level and confirm setting parameter
∧
Up
Increase of date and function code
∨
Down
Decrease of date and function code
>>
Shift
It can select the displaying parameters circularly on the stop
displaying state and the running displaying state. It can also
select the modification bit of the parameters when modifying the
parameters.
RUN
Running
In the keypad operation mode, it is used for running and
operating the controller.
STOP/
RESET
Stop/reset
The key is for stopping the running when the controller is in the
running state, and for resetting the faulty status.
QUICK
Quick key
Enter or exit the quick menu
MF.K
Multi-function
selection
Display and remove of error message
3.4.3 Viewing and Operation Instruction of Function Code
3-level menu operational procedures:
1)
NICE3000 adopt 3-level menu to conduct the parameter setting. It
’
s convenient to query and
modify function code and parameter.
3-level menu include: function parameter group (first level)
→
function code (second level)
→
function code setting (third level). Operation procedures are as follows (Fig 3-23):
0.000
50.00
F0-06
F0
Date show
1-level
2-level
3-level
PRG/
ENTER
PRG
PRG
PRG
ENTER
ENTER
Change group
Modify code
Change function code
Fig 3-23 level menu operational procedures
Instruction
:
When in 3rd menu, system can be backed to 2nd menu by pressing PRG or
ENTER . The difference between the two ways are as follows
:
it saves parameter after
pressing ENTER , then back to next function code in 2nd menu; And it does not save
parameter after pressing PRG , then keep staying at the current function code in 2nd menu.
Example: Change function code F0-06 from 50.00Hz to 15.00Hz (bold means flash bit).
50.00
F0-06
F0-00
ENTER
ENTER
50.00
10.00
10.00
15.00
F0-07
ENTER
F0
PRG
0.000
F0
PRG
PRG
Display in stop
Fig 3-24 Example for Parameter Change
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...