Installation and wiring NICE3000 User Manual
72
Type
Configure of brake resistance
Brake unit
MCTC- DBR-4001
300W ,200
Ω
Standard equipment
MCTC- DBR-4002
600W ,220
Ω
MCTC- DBR-4003
1100W ,130
Ω
MCTC- DBR-4005
1600W ,90
Ω
MCTC- DBR-4007
2500W ,65
Ω
MCTC- DBR-4011
3500W ,43
Ω
MCTC- DBR-4015
4500W ,32
Ω
MCTC- DBR-4018
5500W ,25
Ω
MCTC- DBR-4022
6500W ,22
Ω
MCTC- DBR-4030
9000W ,16
Ω
MCTC- DBR-4037
11000W ,13
Ω
External equipment
MCTC- DBR-4045
13500W ,10
Ω
MCTC- DBR-4055
16500W ,9
Ω
4.3.2 Electric wiring
Electric wiring include three parts
:
Controller main circuit, main control board wiring and
encoder wiring.
Main circuit connection and terminal function
1)
main circuit:
a)
Fig 4-3 Main Circuit Wiring
terminal function
:
b)
Terminal
Name
Instruction
R
、
S
、
T
3-phase power input
terminal
Connect 3-phase AC380V
(+)
、
(-)
Positive and negative
terminals of DC bus
Shared DC bus input, for controller above 37kW,
they are for brake unit
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...