NICE3000 User Manual Function parameter description
137
Binary bit Parameter Display or
not
Binary bit
setting
Binary bit Parameter Display or
not
Binary bit
setting
Bit4
Output
current
Display
1
Bit12
Car top
input state
Not
display
0
Bit5
Output
frequency
Display
1
Bit13
Car top
output
state
Not
display
0
Bit6
Input
terminal
low bit
Not
display
0
Bit14
System
state
Display
1
Bit7
Input
terminal
high bit
Not
display
0
Bit15
Preset
torque
current
Not
display
0
The setting binary number is 0100100000110111, the corresponding algorism number is 18487,
and FA-01 should be set as18487.These displaying parameter can be switched by shift key in
control keyboard.
FA-02
Stop display
Default
65535
Min. Unit
1
Setting Range
0
~
65535
This function code is made up of binary numbers with 16 emic that displays 12 kinds of
stopping state parameters. The displaying parameters can be switched by shift key on the
control keyboard in the following list. The setting way is the same with FA-01.
Bit0
Rated speed
Bit6
Current station
Bit1
Bus voltage
Bit7
Car load
Bit2
Input terminal low bit
Bit8
Rated lift slowdown distance
Bit3
Input terminal high bit
Bit9
Car top input state
Bit4
Output terminal
Bit10
Car top output state
Bit5
Current floor
Bit11
System state
The stopping and running parameters are useful and important reference for the technician
when adjusting the lift. The specific meaning of each variable is described as follows:
Running speed: is the actual speed when the lift is running. It
’
s the feedback speed of rotation
encoder whose maximum value is the fasted speed (F0-03) of the lift, with the unit m/s.
Setting speed: is the speed of NICE3000 when it
’
s running. It
’
s gained by the theoretical
calculations with the unit m/s.
Bus voltage: is the value of DC bus voltage with the unit V.
Output voltage: is the valid value of equivalent voltage when NICE3000 outputs PWM wave
form, with the unit V.
Output current: is the valid value of the actual current when NICE3000 drive motor is running,
with the unit A.
Output frequency: is the actual frequency when the motor is running with the unit Hz. This
parameter is fixed corresponding with the running speed.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...