Function parameter description NICE3000 User Manual
112
F2-10
Running direction
Default
0
Min. Unit
1
Setting Range
l0
、
1
0: The same direction
1: The running direction choose reversal, position pulse direction choose reversal
2: The same running direction, position pulse direction choose reversal
3: The running direction choose reversal, position pulse direction choose the same
In this function code, it can choose reversal of running direction (Motor
’
s running direction
when the connection of motor didn
’
t change), and position signal (Means F4-03 used for
identify the pulse direction of lift
’
s position). For example, After the installation of the lift, up
running inspection while lift
’
s actual running direction is down running, so running direction
needs choose reversal; while up running inspection, the position pulse F4-03 reduced (position
lower), so position pulse direction needs choose reversal.
Please pay attention to the setting of parameters while recover the default.
6.4 F3 Group Running Control Parameters
F3-00
Starting speed
Default
0.010m/s
Min. Unit
0.001m/s
Setting Range
0.000
~
0.030m/s
F3-01
Time keeping
Default
0.150s
Min. Unit
0.001s
Setting Range
0.000
~
0.500s
Setting of starting speed can increase the ability to overcome the static friction. But if the setting
of starting speed is too big, it can generate impact feeling at starting time. The using of two
parameters can smooth of lift starting.
F3-02
Acceleration
Default
0.600m/s
2
Min. Unit
0.001m/s
2
Setting Range
0.200
~
2.000m/s
2
F3-03
Inflexion speedup time 1
Default
2.500s
Min. Unit
0.001s
Setting Range
0.300
~
4.000s
F3-04
Inflexion speedup time 2
Default
2.500s
Min. Unit
0.001s
Setting Range
0.300
~
4.000s
The three function codes decide the S curve parameters of lift speedup running:
F3-02 is acceleration of S curve of lift speedup running.
F3-03 is the time which is cost from 0 to the parameter F3-02 of S curve speedup stage. The
bigger this parameter is, the slower curve inflexion is.
F3-04 is the time which is taken from the change of acceleration from 0 to that of F3-02 in the S
curve speedup stage. The bigger this parameter is, the slower the flatter the curve inflexion is.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...