Function parameter description NICE3000 User Manual
104
Function
code
Name
Default
Min. Unit
Setting Range
F1-01
Rated power
Depending on
the model
0.1kW
1.1
~
75.0kW
F1-02
Rated voltage
380V
1V
0
~
440V
F1-03
Rated current
Depending on
the model
0.01A
0.00
~
655.00A
F1-04
Rated frequency
50.00Hz
0.01Hz
0.00
~
99.00Hz
F1-05
Rated rotation speed
1460rpm
1rpm
0
~
3000rpm
Please set according to the nameplate parameters of the motor.
The system has motor parameter auto-tuning function. Only when the motor
’
s parameter is
setting correctly can the system complete parameter tuning function correctly to fulfill good
vector control function.
Function
code
Name
Default
Min. Unit
Setting Range
F1-06
Stator resistance
(Asynchronous motor)
Depending on
the model
0.001
Ω
0.000
~
30.000
Ω
Encoder initialized angle
(Synchronous motor)
Depending on
the mode
0.1
°
0
~
359.9
°
F1-07
Rotor
resistance(asynchronous)
Current angle(sync)
Depending on
the model
0.1
0.001
Ω
0.000
~
30.000
Ω
F1-08
Leakage inductance
(Asynchronous motor)
Depending on
the model
0.01mH
0.00
~
300.00mH
Wiring connection
(Synchronous motor)
Depending on
the model
1
0
~
15
F1-09
Mutual inductance
Depending on
the model
0.1mH
0.1
~
3000.0mH
ADC sampling delay
function (sync)
0.0
0.1
0-40
F1-10
No-load current
Depending on
the model
0.01A
0.01
~
300.00A
Selection check of
encoder
’
s signal
0.0
0.1
0-31
To ensure system performance, please set according to the system standard of the motor
arrangement. If the motor power is a lot different from the standard motor power, the
performance of system control will decline.
The parameter F1-06 means different meaning when used in different motors. When it
’
s used
in asynchronous motor, it means the stator resistance. When it
’
s used in synchronous motor,
it means the encoder initialized angle. No matter which motor to be used in, this parameter can
be created after NICE3000 tuning. And users can modify this parameter according to actual
condition.
If the automatic tuning of the motor is completed normally, the setup values in F1-F6 to F1-F10
will update automatically.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...