Function parameter description NICE3000 User Manual
120
It adds the second safety circuit inputting point in order to protect against the accidents
caused by the pick-up of the safety circuit feedback contactor. If both input points are selected
NICE3000 system certificates the normal work of the safety circuit only when both are valid.
Otherwise, the system will be in E4 indication.
30: N.O. input of synchronous motor self-locking feedback
Synchronous motor self-locking contactor can ensure that there won
’
t be far speed running
even if the brake is out of work. It can be set through FE-33.
31: N.O. input of door lock circuit2 feedback
The function of door lock circuit2 is the same with that of door lock circuit1. It
’
s convenient
for the users to separate the signals from the hall door to car door. The door lock is considered
locked only when the two door lock circuit feedback signals are connected.
33
~
63
These 31 parameters are corresponding with parameters 01
~
31.The parameters 01
~
31 input
terminal are set as N.O. input, but the parameters 33
~
63 are set as N.C. input.
Function code
Name
Default
Min. Unit
Setting Range
F5-25
Car top input type selection
64
1
0
~
255
It can set definite types of signals of the car top control panel by bit.
0
:
N.C. input
;
1
:
N.O. input
For example: one lift need set car top input signal type as the following list:
Binary digit
Parameter
Type setting
Binary digit
Parameter
Type setting
Bit0
Font door
beam screen
N.C.
Bit4
Front door-
close limit
N.C.
Bit1
Back door
beam screen
N.C.
Bit5
Back door-
close limit
N.C.
Bit2
Front door-
open limit
N.C.
Bit6
Digital load 3
(full load)
N.O.
Bit3
Back door
-open limit
N.C.
Bit7
Digital Load
4 (over load)
N.C.
The binary system shows 01000000, corresponding decimal system count shows 64.So the
parameter F5-25 is set as 64.
For example: when font door beam screen is N.O. Binary digit shows 01000001, corresponding
decimal system count shows 65.So the parameter F5-25 is set as 65;
Function code
Name
Default
Min. Unit
Setting Range
F5-26
Y1 function selection
1
1
0
~
16
F5-27
Y2 function selection
2
1
0
~
16
F5-28
Y3 function selection
3
1
0
~
16
F5-29
Y4 function selection
4
1
0
~
16
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...