Preface NICE3000 User Manual
6
Standard Function
Serial
number
Function name
Function introduction
Remark
11
re-leveling when
the door is open
The lift stop at the floor station, a large number of
persons or goods entering and leaving, The leveling
fluctuated because of the elastic deformation of
elevator Wire Rope and the rubber. System allows
run automatically at the speed of re-leveling to leveling
station in the state of the door opened
Configure
MCTC-
SCB-A
12
Automatic back to
the base floor
when beyond the setting time and there is no inside-
call and outside-call ,elevators automatically return to
the base station and wait for passengers
Standard
Settings
13
Parallel Operation
Two elevators through Serial communication (can
bus) for data transmission. coordinate outside-call and
improve operational efficiency
Function
Selection
14
Group control
adjustment
operation
Multiple elevators through Serial communication (can
bus) for data transmission. Calculate the most efficient
and effective operation mode in response to outside
calls.
Configure
MCTC-
GCB-A
15
Motor parameter
auto-tuning with no
load
For induction motors control system can automatically
recognize the motor resistance, inductance, control
parameters, no-load current to accurately control the
motor. As for the permanent magnet synchronous
motor, control system can identify the angle of rotary
encoder
Permanent
magnet
synchronous
motor for
identify
the rotary
encoder
angle
16
Shaft parameters
of self-learning
Before the first run, system must self-learn the shaft
parameters. Including the story on each floor, forced
deceleration switch, limit switch position.
Standard
Settings
17
Elevator-locking
function
In automatically run state, after the elevator locked,
the system eliminates all calls registered and then
return to elevator-locked base station then open the
door. After that the elevator stops running, closing the
light and fan in car. When the lock switch has been
reset the elevator re-entered to normal service state.
Standard
Settings
18
Full load by pass
Under the condition of run automatically without the
driver, when the car with full load (generally is 80
℅
rated load) the elevator does not respond to outside-
calls in passing floor. However, this time outside-calls
can still be registered; it will be serviced next run-time
(single control), or by other elevator services (group
control)
Standard
Settings
19
lighting
、
fan
energy-saving
function
When beyond the setting time and there is no inside-
call and outside call the elevator will automatically
turn off the light and fan in car
Standard
Settings
20
Floor service set
System can be flexible choose to shut down or
activate one or more elevators service floors and stop
floors for its own needs
Function
Selection
21
Car location
automatically
correct
when the elevator run to the end station ,the system
automatically inspection and rectification of the
location information based on the first level forced
deceleration switch .At the same time, assisted by a
special rate of forced deceleration
Standard
Settings
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...