Function parameter description NICE3000 User Manual
132
Function code
Name
Default
Min. Unit
Setting Range
F7-00
Testing floor 1
0
1
0
~
F6-00
F7-01
Testing floor 2
0
1
0
~
F6-00
F7-02
Testing floor 3
0
1
0
~
F6-00
F7-03
Testing floor 4
0
1
0
~
60000
It can set the target floor when the lift is in adjusting or service. Its setting range is from 0
~
F6-
00,but the commands of current floor and less than the floor F6-01 aren
’
t administered.
0
:
Testing floor is invalidation. Testing floor 1 is the same with car call. Testing floor 2 is the
same with landing up call. Testing floor 3 is the same with landing down call. The command is
durative availability until code set to 0 instead.
NICE 3000 can run at random. There are 5s in each running interval when simulating the
daily running state. The times set by F7-03 are generated by the times of target floors occur at
random. If the setting time is over 60000, the random running will keep on until the user sets
7-03 as 0.
F7-04
Landing call enable
Default
0
Min. Unit
1
Setting Range
0
、
1
0
:
Landing call allowable;
1
:
Landing call forbidden
F7-05
Door open enable
Default
0
Min. Unit
1
Setting Range
0
、
1
0
:
Door open allowable, door operator button useful;
1
:
Door open forbidden, door operator button unuseful and door don
’
t automatically open.
F7-06
Over load function selection
Default
0
Min. Unit
1
Setting Range
0
、
1
0
:
Over load running forbidden;
1
:
Over load running allowable. When over load running is allowed, lift comes into over load
state, light of over load lights, and lift doesn
’
t respond to landing call, non-stop running to
target floor. Please set 0 when it
’
s in normal using.
F7-07
Limit enable
Default
0
Min. Unit
1
Setting Range
0
、
1
0
:
End switch availability;
1
:
End switch invalidation. Only use it when checking limit switch.
:
This F7 group functions are used by persons who possess professional
competency. Please pay more attention. The operator is in charge of the responsibilities.
Please make sure that the setting of the F7 group parameters is 0.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...