Preface NICE3000 User Manual
8
Standard Function
Serial
number
Function name
Function introduction
Remark
36
Anti-nuisance
function
System identifies the number of passengers in car and
Automatically determines the number of passengers
inside and comparison with the instructions registered
in car. If an excessive number of calls registered, then
the system considers it is anti-nuisance status and
cancels all the calls in car. You need to re-register
correct calls
Configure
Car weighing
equipment
37
Full selective
when the elevator running in automatic or driver state
will be responded to inside-call signal meanwhile
responded to hall call button signals, any service floor
can call the elevator by register the up and down
signal
Standard
Settings
38
Up selective
when the elevator running in automatic or driver state
will be responded to inside-call signal meanwhile
responded to outside-call button signals, any service
floor can call the elevator by register the up signal
Function
Selection
39
Down selective
when the elevator running in automatic or driver state
will be responded to inside-call signal meanwhile
responded to outside-call button signals, any service
floor can call the elevator by register the down signal
Function
Selection
40
separate wait
only the system with parallel or group control can
select this function, when elevators in parallel or group
control in the same floor, parallel or group control will
began to spread the elevators, make the elevator run
to the free floor
Function
Selection
41
Current aslant
removal
when use permanent magnet synchronous motor, after
the elevator decelerating and stopping, the maintain
current of the motor removed by the slope way to
abnormal noise of the motor during the process
Function
Selection
42
User Preferences
inspect
Users can find the system parameters which is
different from the factory parameters by this function
Function
Selection
43
Peak service
Parallel peak is in the peak time set, if the inside-call
from this peak floor is more than 3, then system in
peak service. the inside-call effective all the time, the
elevator is free it will be go to this floor
Function
Selection
44
Real-time clock
management
System have real-time clock chip to guarantee the
clock work normal in 2 years
Function
Selection
45
time-sharing
services
Flexible setting the time-sharing service time period
and the corresponding time-sharing service floors.
Function
Selection
46
Guard floor at night
Protect floor of elevator, when 22 o
’
clock to 6
o
’
clock the Protect floor is valid, the elevator will
be running to the Protect floor every time when the
elevator running, stop at the protect floor to open
the door and then run to the target floor to improve
security
Function
Selection
47
Drivers reversing
Drivers choose the direction of the elevator through a
special button
Standard
Settings
48
Deputy operation
box operation
manipulation matching box can be selected if the
system have the main control box, the manipulation
matching box also equipped with a command button
and the door button switch and the function is the
same as the main control box
Standard
Settings
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...