6.14 FD Group Communication Parameters
Function code
Name
Setting Range
Default
Min. Unit
FD-00
Baud rate setting
0
:
300bps
1
:
600bps
2
:
1200bps
3
:
2400bps
4
:
4800bps
5
:
9600bps
6
:
19200bps
7
:
38400bps
5
1
FD-01
Data format
0: No check-out
1: Even check-out
2: Odd check-out
0
1
FD-02
Local address
0
~
127
,
0
:
Broadcasting address
1
1
FD-03
Responding delay
0
~
20ms
10ms
1ms
FD-04
Communication
delaying time
0.0
~
60.0s
,
0.0s
:
invalidation
0.0s
0.1s
This group function codes can set NICE3000 RS232 Serial communication parameter for up bit
motor monitoring software communication. FD-00 sets Serial communication baud rate, FD-01
sets Serial communication data frames format, and FD-02 sets the local address of controller.
These parameters
’
setting must be the same with the Serial communication parameters of
controller so that they can communicate normally. FD-03 sets the delaying time of controller
transmitting data by the Serial port. FD-04 sets the overtime of the Serial port communication,
and the time of frame data transmitted must be within the time of FD-04 setting. Otherwise
communication error may occur.
6.15 FE Group Lift Function Setting Parameters
FE-00
Collective selective mode
Default
0
Min. Unit
1
Setting Range
0
、
1
、
2
0
:
Full selective, lift responds to up call and down call.
1
:
Down selective, lift only responds to hall down call and doesn
’
t respond to hall up call.
2
:
Up selective, lift only responds to hall up call and doesn
’
t respond to hall down call.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...