Structure of the control system and the component introduction NICE3000 User Manual
40
5th floor, successively set as 7,8,9..., and if there is no plate in the 3rd and 4th floors, from the
5th floor, successively set as 5,6,7....
Input part
Plug the wiring interface of the lift-locked and fire-emergency switches into the socket of JP1
and JP2, plug the general up/down buttons wiring interface into the JP3 and JP4,, and plug the
disabled up/down buttons wiring interfaces into the JP5 and JP6.
Plug the wiring interface of the MOD-bus communication cable into CN1.
Remark
:
Do not set the floor address of the hall call board as 0;
a)
The STP is recommended for the communication wiring to avoid the external
b)
interference to the communication signal;
It
’
s recommended to use the shielded cable as the communication signal wire;
c)
Please wiring firmly according to the terminal symbol;
d)
Terminal input and button output
Terminal
Function
JP1
The pin 2 and 3 of lift-locked switch interface are the pin of switching value, the pine 4 is
the lift-locked lamp output.
JP2
Fire-emergency switch interface, the pin 2 and 3 are the switching value wiring pin, pin 4
is the fire-emergency indicator output
JP3
General up call button interface, the pin 2 and 3 are the switching value wiring pin, the pin
1 and 4 are the power wiring pin used for the control of button lamp.
JP4
General down call button interface, the pin 2 and 3 are the switching value wiring pin, the
pin 1 and 4 are the power wiring pin used for the control of button lamp.
JP5
Disabled up call button interface, the pin 2 and 3 are the switching value wiring pin, the
pin 1 and 4 are the power wiring pin used for the control of button lamp.
JP6
Disabled down call button interface, the pin 2 and 3 are the switching value wiring pin, the
pin 1 and 4 are the power wiring pin used for the control of button lamp.
CN1
MOD-bus communication and power wire terminal, 4PIN interface the pin 2 and 3 are the
pin of MOD-bus communication wire, the pin 1 and 4 are the power wiring pin.
CN2
Relay output, see Fig.3-9-3 for the definition details
Table 4 I/O Terminal definition
JP1-JP6 are 4PIN interfaces. The pin details refer to Fig. 3-11
MP24
KEY- I N
KEY- LED
1
3
4
2
Fig 3-11 4PIN interface
Relay output
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...