It means the re-leveling speed when the lift is in the door zone. Because the length of leveling
plate is different in different system, the parameter adjusting can assure the landing accuracy of
re-leveling. It is used when chooses the re-leveling function through FE-32..
F3-11
Low-speed running
Default
0.250m/s
Min. Unit
0.001m/s
Setting Range
0.100
~
0.630m/s
It can set the low speed of running when the lift is running in inspection or shaft auto-tuning.
F3-12
Switching position of the NO.1 up
force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
F3-13
Switching position of the NO.1
down force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
F3-14
Switching position of the NO.2 up
force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
F3-15
Switching position of the NO.2
down force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
F3-16
Switching position of the NO.3 up
force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
F3-17
Switching position of the NO.3
down force reducer
Default
0.00m
Min. Unit
0.01m
Setting Range
0.00
~
300.00m
NICE3000 can set 3 pairs of switches of force reducer at most. Its setting position is: the
sequence is followed by the installation of NO.1, NO.2, and NO.3 force reducer switches from
the end to the middle of the shaft. That means the switch of the NO.1 is built near the terminal
landing.
In the low-speed lift, there may be only one pair of switches of force reducer. And there are two
or three pairs of switches of force reducer in the high-speed lift. The system can self-motion
monitor the running speed when lift run to the switching position of force reducer, and prevent
car and counterweight from resting the butter because of the abnormity speed.
This parameter of distance means the distance from switch position to the lowest floor. It can
self-motion note according to the lift auto-tuning.
Propositional position:
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...