Function parameter description NICE3000 User Manual
106
First, set F0-01 as 0: the control mode selection is the operating panel command channel.
Set F1-00 as 0 by actual motor types: asynchronous motor. Then set F1-01
、
F1-02
、
F1-03
、
F1-04
、
F1-05 according to the nameplate parameters of motor.
If the motor can be separated from load, the parameter F1-11 selects 2(motor no-load tuning).
Then press RUN of the operating panel and the motor can automatically run. The control
automatically counts these parameters as follows: F1-06 (stator resistance), F1-07 (rotor
resistance), F1-08 (leakage inductance), F1-09 (mutual inductance) and F1-10 (no-load
excitation current). The motor tuning is then over. If the system appears over current, please
increase the parameter F1-10, but don
’
t exceed 20%.
If the motor can
’
t be separated from load, the parameter F1-11 selects 1(motor with-load
tuning).Then press RUN of the operating panel and the motor can automatically tune. The
controller only automatically counts three parameters: stator resistance, rotor resistance, and
leakage inductance. It automatically counts mutual inductance and no-load current of motor as
well.
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...