NICE3000 User Manual Structure of the control system and the component introduction
55
In the third level menu, if the parameter has no flash bit, it means the function code cannot be
changed and the possible reasons are:
This parameter of this function code cannot be changed, such as the actually detected
1)
parameter and running record parameter.
This function code cannot be changed in operating status and can only be changed when
2)
the controller is stopped.
To shift the status display parameters by key
�
>>
a)
Example:
Output
terminal
High of input
Low of input
Currently
place
load
Decelerate distance of rated speed
Rated speed
Bus voltage
Fig 3-25 Example of Parameter Changing in Stopping State
In stopping and running status, the LED can display several status parameters, Whether to
display the status parameters is dependent on the bit setting of FA-01 (running parameter) and
FA-02 (stopping parameter). Through key
�
>> , user can shift the display in sequence and
display the stopping or running status parameters circularly.
In stopping state, there are 12 status parameters for NICE3000, user can shift to display the
parameters circularly by key
�
>>
�
. The parameters are: rated speed, bus voltage, low bit
of input terminal, high bit of input terminal, output terminal, currently floor, currently place, car
load, decelerate distance of rated speed, car top input state, car top output state and system
state. Users can select the desired parameters through the bit of FA-02.
In running state, there are 16 state parameters for NICE3000. Users can shift to display the
parameters circularly by key
�
>>
�
. The parameters are: running speed, rated speed, bus
voltage, output voltage, output current, output frequency, low bit of input terminal, high bit of
input terminal, output terminal, currently floor, currently place, car load, input of CTB-A, output
of CTB-A, system state, and advance torque current. Users can select the desired parameters
through the bit of FA-01.
Error information reading
3)
When error occurs in the controller, the error information will be displayed on the panel. It is
convenient to find reasons for the error and get rid of the error as soon as possible.
The controller can save the last 11 error codes. Users can read the first error code in the
following way:
FC-06
FC-00
FC
0000
0.000
F0
PRG
ENTER
ENTER
Date Display
Fig 3-26 way of error information reading
Summary of Contents for MCTC-CTB-A
Page 12: ...Preface NICE3000 User Manual 12...
Page 15: ...Safety information and attention items 1...
Page 21: ...Product information 2...
Page 29: ...3 Structure of the control system and the component introduction...
Page 69: ...4 Installation and wiring...
Page 80: ...Installation and wiring NICE3000 User Manual 80...
Page 81: ...5 Function parameters tables...
Page 100: ...Function parameters tables NICE3000 User Manual 100...
Page 101: ...6 Function parameter description...
Page 153: ...7 System typical application and adjustment...
Page 172: ...System typical application and adjustment NICE3000 User Manual 172...