ECDIS User Guide
System
65900012
13-33
PCIO Diagnostic Form
The PCIO diagnostics form records the error rate on received data from
serial input ports TSCA, TSCD and TCSE (Serial Ports 1, 2 and 3) on the
PCIO. If any data errors are received on these PCIO serial inputs the
number of error messages over a selected time period appears against the
serial input line. Any PCIO data errors are listed in a log file, which is
included in a fault report. The PCIO Diagnostic Form is available for display
to a non-logged on user.
1. To access, click on the
PCIO +
button, highlight PCIO diagnostic
form in the tree menu and click on the
Display Selected
button at
the bottom of the tab folder. A Serial Input Error Level Diagnostic
Form is displayed. The form is a table with each line representing
the PCIO serial inputs listed above.
2. The number of errors received in the default time of one second will
appear on the serial input line. To change the time period over
which the errors are received, click on the drop down arrow and
select from 1 second, 10 seconds or 60 seconds.