ECDIS User Guide
Targets
65900012
10-29
AIS Display
The AIS Display window includes:
•
Settings All Nodes
•
Filter Settings
•
Other
•
Target Count All Nodes
This may be quickly accessed from the main
screen by left clicking on the
AIS
button on the
upper toolbar.
Settings All Nodes
AIS Input
AIS input and the display of AIS targets is
turned on or off on all nodes by ticking the
Enable Input
check box.
AIS Input can only be enabled when
valid sensor data is being transmitted.
Activate on CPA/TCPA/BCR
When this check box is enabled (default mode)
a sleeping AIS target is automatically activated
when the target infringes its CPA/TCPA or BCR
limits shown in the Target Data tab folder.
If this setting is disabled all sleeping AIS targets
are rendered as dotted lines (see `AIS
Rendering Conditions’ in AIS Targets) and not
activated when target data limits are infringed.
WARNING!
THIS SETTING SHOULD NORMALLY BE ENABLED.
DISABLING AUTO-ACTIVATION FOR COLLISION AVOIDANCE MAY
RESULT IN POTENTIALLY DANGEROUS TARGETS NOT RAISING
AN ALERT