Alerts
ECDIS User Guide
7-24
65900012
Alert Type
Description
Priority
Notes
I/O Device
Unavailable
I/O Device Unavailable
Warning
Inaccurate Chart
Positions on this chart are inaccurate, because this chart does not
provide a mapping to standard WGS-84 coordinates.
Warning
Incompatible PCIO
firmware
PCIO firmware required is v1.04 or later.
Warning
Incorrect Compass
Ratio.
Configured compass ratio is incorrect for current board type.
Warning
Internal Error
An unrecoverable internal error has occurred, please restart the
equipment
Warning
Interswitch Comms
Interswitch communications failed. Transceiver source unknown.
Top Unit settings may be invalid (e.g. Heading Marker Offset,
Turning Unit Offset)
Warning
Interswitch Model
Conflict
The interswitch model conflicts with the configured model
Warning
Interswitch Request
Failed
The Interswitch request failed.
Warning
Invalid Datum In Use
Datum in use is not WGS84.
Warning or
Caution
Depending on
configuration
Invalid Network
Config
Invalid network configuration detected.
Warning
IO Comms Interrupted
IO communications interrupted on an Alert Management Interface. Caution
IO Comms Reception
IO communications unavailable for Alert Management Interface.
Caution
Local Time Offset
Unusable
Sensor Local Time Offset Integrity VisionMaster FT
Alarm or
Caution
Depending on
configuration
Summary of Contents for Visionmaster FT ECDIS
Page 1: ...ECDIS User Guide Northrop Grumman Sperry Marine B V Part Number 65900012...
Page 2: ......
Page 4: ...ECDIS User Guide 65900012 iii Intentionally Blank...
Page 22: ...Table of Contents ECDIS User Guide xx 65900012...
Page 24: ...Overview ECDIS User Guide 1 2 65900012 Single System...
Page 42: ......
Page 68: ......
Page 132: ......
Page 284: ......
Page 312: ......
Page 396: ......
Page 404: ......
Page 462: ......
Page 478: ......
Page 484: ......
Page 520: ......
Page 531: ......