System
ECDIS User Guide
13-26
65900012
Unauthorized System
If the system is not authorized the tab folder
states that the system is unauthorized and will
revert to a degraded state of functionality,
counting down from 7 days after the
authorization initially failed.
When the system is in a degraded state
there is no target tracking or chart data
available.
A temporary password can be supplied by your
VisionMaster supplier on request. The
password will contain:
•
System PIN
•
Product type identifier
•
Expiration date (typically 30 days from the
time it is requested).
Enter the password in the
Temporary
Authorisation Password
field and click the
Submit
button. The system verifies the
password and, if correct, the node is
temporarily authorized and a PIN is displayed.
When a password has been entered and its expiry date has not yet been
reached, the system will run as fully authorized.
When the node is running on a temporary password, a warning is given,
repeated once per day, indicating when the password will expire. After the
password expiry date has been reached, the node reverts to an
unauthorized state.
If a security block authorization fails on any node, and this is not remedied
by entry of a password the system will do the following:
•
produce a warning every 15 minutes.
•
run normally on that node until 7 days (calendar time) have passed
since the authorization initially failed.
•
operate in a state of degraded functionality after the 7-day period
expires.
Summary of Contents for Visionmaster FT ECDIS
Page 1: ...ECDIS User Guide Northrop Grumman Sperry Marine B V Part Number 65900012...
Page 2: ......
Page 4: ...ECDIS User Guide 65900012 iii Intentionally Blank...
Page 22: ...Table of Contents ECDIS User Guide xx 65900012...
Page 24: ...Overview ECDIS User Guide 1 2 65900012 Single System...
Page 42: ......
Page 68: ......
Page 132: ......
Page 284: ......
Page 312: ......
Page 396: ......
Page 404: ......
Page 462: ......
Page 478: ......
Page 484: ......
Page 520: ......
Page 531: ......