User Guide
98
o
ption
D
escription
e
xampLe
Left
Positions track names on the lower end
of the meter scale.
i
The example shows solid meters.
Left w/ramp
Applies a gradient to the background
color, and positions track names on the
lower end of the meter scale.
Right
Positions track names on the higher end
of the meter scale.
Setting Meter Ballistics and Peak Hold
Audio meter ballistics is the manner in which a visual meter responds to audio
signal levels. The ballistics for all meters is globally set for the mixer via System
settings.
To configure meter ballistics:
1. Press the MENU button.
2. Turn and press the Headphone encoder to select SYSTEM > Meter Ballistics.
Options include:
o
ptions
D
escription
VU Only
Volume Units (VU) meter ballistics correspond closely to how the human
ear perceives loudness. This provides a good visual indication of how loud
a signal will be. In VU mode, the attack and decay of the meter signal is
300 mS. VU meters provide good visual indication of how loud a signal will
be, but provide poor information of actual signal peaks.
Summary of Contents for 664
Page 1: ... 664 Field Production Mixer with Integrated Recorder User Guide ...
Page 4: ...User Guide 4 ...
Page 20: ...User Guide 20 ...
Page 48: ...User Guide 48 ...
Page 60: ...User Guide 60 ...
Page 68: ...User Guide 68 ...
Page 76: ...User Guide 76 ...
Page 88: ...User Guide 88 ...
Page 108: ...User Guide 108 ...
Page 112: ...User Guide 112 ...
Page 118: ...User Guide 118 Status Bar Viewing Area Tab Bar ...
Page 140: ...User Guide 140 ...
Page 146: ...User Guide 146 ...
Page 174: ...User Guide 174 ...
Page 180: ...CS 688 180 ...