99
SYSTEM
o
ptions
D
escription
Peak + VU
In Peak + VU mode, the perceived loudness (or VU) is simultaneously
displayed as a standard bar while the peak signal is displayed as a single,
independent segment above the VU. By default, meter ballistics is set to
Peak + VU.
Peak Only
Peak-reading ballistics (PPM) correspond to actual signal peaks, but do not
necessarily correspond to perceived signal loudness. Peak meters have an
instantaneous attack and a slow decay to allow visual monitoring of peak
activity. Peak metering is useful in digital audio workflows. In the digital
realm, signal overload can cause immediate distortion.
Setting Peak Hold
When meter ballistics is set to Peak + VU or Peak Only, peak hold displays the
last highest peak value on the meter as a separate, individual meter segment.
By default, this meter segment will remain visible for 1 second. This time frame
is called the Peak Hold, and it may be adjusted or disabled altogether.
To modify the Peak Hold time for meters:
1. Press the MENU button.
2. Turn and press the Headphone encoder to select SYSTEM > Meter Peak Hold
Time.
Options include:
o
ptions
D
escription
1 - 5 sec
Sets the Peak Hold time to display the highest peak value for the selected
time, from 1 to 5 seconds.
Infinity
Sets the Peak Hold time to display the last highest peak value indefinitely
until a higher peak is reached.
Off
Does not hold peak values.
Setting up Date and Time Parameters
Properly setting the time and date is important for file metadata, file system
functioning, and some timecode functions. Setting the correct GMT time zone
and daylight savings values is also vital for correct data stamping on the exFAT
file system.
The 664 has several System settings related to date and time parameters:
p
arameter
D
escription
o
ptions
Time Format
Sets the format used for times displayed by the
mixer. By default the format is set to 12 hours.
• 12hr
• 24hr
Date Format
Sets the format used to indicate the date, used
in metadata. By
default, the format is set to two-digit increments
for month/day/year (mm/dd/yy).
•
mm/dd/yy
•
dd/mm/yy
•
yy/mm/dd
Summary of Contents for 664
Page 1: ... 664 Field Production Mixer with Integrated Recorder User Guide ...
Page 4: ...User Guide 4 ...
Page 20: ...User Guide 20 ...
Page 48: ...User Guide 48 ...
Page 60: ...User Guide 60 ...
Page 68: ...User Guide 68 ...
Page 76: ...User Guide 76 ...
Page 88: ...User Guide 88 ...
Page 108: ...User Guide 108 ...
Page 112: ...User Guide 112 ...
Page 118: ...User Guide 118 Status Bar Viewing Area Tab Bar ...
Page 140: ...User Guide 140 ...
Page 146: ...User Guide 146 ...
Page 174: ...User Guide 174 ...
Page 180: ...CS 688 180 ...