419050/B
359
Context
It is always best to do make the noise/speed curve under realistic conditions. This means
that all relevant vessels systems should be in use as under normal operations. However,
if you experience abnormally high noise levels, you may want to repeat the test with
"silent ship" settings. To isolate noise sources, turn individual vessel systems on or off to
monitor any changes in the noise level.
Procedure
1
Make sure that the water depth under the keel permits you to lower the transducer.
2
Lower the transducer to its bottom position.
3
If necessary, establish a separate communication line with the bridge to verify
the vessel speed during the test.
4
Make the following preparations.
a
Select the
Horizontal
tab to open the menu.
b
Set
TX Power
to
Off
.
c
Select the
Setup
tab to open the menu.
d
Select
Test
on the
Setup
menu to open the
System Test
menu.
e
Select
Test Config
to open the
Test Config
parameter dialog.
f
Select
Noise & VR
to select the
Noise test
settings.
g
Select
OK
to save the settings and close each parameter dialog box.
h
Select
Test
on the
Setup
menu to open the
System Test
menu.
i
Observe the echo level shown in the
Echo Level
"button".
5
Repeat the following cycle for each vessel speed:
a
Ask the bridge to set the speed.
b
Observe the
Status
parameter dialog box in the bottom right corner of the SC90
presentation. Make sure that the dialog box presents the requested speed.
c
On the Operating Panel, press
Train right
and
Train left
(arrows) to rotate the
audio line to the different bearings listed in the result table.
d
Read the current echo level displayed by the
Echo Level
"button".
Record the values in the result table.
e
Ask the bridge to set the next speed.
6
When all the measurements have been made, type the data (speed and noise) into a
spreadsheet to create the curve.
7
Hoist the transducer to its upper position.
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...