Environmental inspection of the Transceiver Unit
Satisfactory environmental conditions are important to ensure long and trouble-free
operation of the Transceiver Unit. An environmental inspection of the Transceiver Unit
is required to verify the quality of the sonar room.
Prerequisites
The SC90 is installed as specified in this manual. You need the following equipment:
• Thermometer
• Hygrometer
Context
The
sonar room
is the compartment in which the Transceiver Unit is installed.
Procedure
1
Make sure that the compartment ("sonar room") in which the Transceiver Unit is
installed is clean and dry.
2
Make sure that the ambient temperature in the sonar room meets the environmental
specifications.
a
Make sure that the temperature in the sonar room is controlled using a suitable
ventilation system.
Record the type of ventilation system that is installed.
b
Make sure that the temperature in the sonar room is monitored.
c
Measure the ambient temperature in the sonar room when the SC90 is switched
off.
d
30 minutes after the SC90 has been switched on and put to normal operation,
measure the ambient temperature one more time.
Record the values in the result table.
3
Make sure that the relative humidity in the sonar room meets the environmental
specifications.
a
Measure the relative humidity in the sonar room.
b
30 minutes after the SC90 has been switched on and put to normal operation,
measure the relative humidity one more time.
Record the values in the result table.
4
Make sure that the sonar room, the SC90 Transceiver Unit and the mounting
brackets have not bee subjected to corrosive attacks.
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...