358
419050/B
4
Verify that the measured voltages are within the permitted tolerances.
5
Close the Power Supply Unit.
Result
Record the values in the result table.
+72 VDC
+12 VDC
+4.9 VDC
Requirements:
+72 VDC ± 2 VDC
+12 VDC ± 1 VDC
+4.9 VDC ± 0.1 VDC
Requirements
Results
All measured voltages are within the permitted tolerances.
Date and signature:
Making a noise/speed curve to determine vessel noise
The performance of the SC90 will always be limited by different noise sources. During
the Installation Manual, accurate noise measurements are done for different vessel
speeds. The weather and sea conditions for the noise measurements will be those at
the time of the test.
Prerequisites
The SC90 is turned on, and it is working normally. The vessel is at sea. Recommended
minimum depth is 100 metres.
If the SC90 is operated from any other compartment than the bridge, an open two-way
oral communication channel with the bridge is required.
You need the following equipment:
• Personal computer
• Spreadsheet program
For the best possible conditions to complete the test, the ship must be "silent".
• There must be no other vessels in the vicinity.
• As much machinery as possible must be switched off. It is particularly important to
switch off electrical motors, as well as cooling systems and hydraulic pumps that
may cause electric noise.
• To prevent interference, all other hydroacoustic instruments must be switched off.
Simrad SC90 Installation Manual
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...