302
419050/B
a
Use the
Train left
and
Train right
(arrow) buttons on the Operating Panel to turn
the white audio line (beam) to the most noisy area in the presentation.
b
Make sure that the echo level for the selected audio beam is displayed in the
Echo Level
button on the
System Test
menu.
c
Adjust the
Gain
until the echoes on the images on the SC90 presentation are
dynamic, and you can distinguish between the individual echoes.
7
Read the current echo level displayed by the
Echo Level
"button".
a
Change the
Frequency
to the next available setting.
b
Repeat this for each frequency that is shown in the result table.
c
Fill in the test results in the table provided.
8
Connect the transceiver plug to the Transceiver Unit output.
Result
Requirements
Results
Maximum noise value (in dB) shown in the
Echo Level
button is ≤46 dB.
Maximum noise value measured in the
Echo Level
button is:
Date and signature:
For each transmit frequency (in kHz), write down the measured noise level (in dB).
82.5
83
83.5
84
84.5
85
Further requirements
If the noise level is higher than specified, you must check the reason(s) for this.
• Check the grounding of the Transceiver Unit.
• Verify that other electric equipment and/or machinery on board, such as cooling
systems, hydraulic pumps, electric motors etc, do not influence on the noise reading.
Switch off as much machinery as possible, especially electrical motors.
• Check for interference from other hydroacoustic systems.
• Check for environmental noise, such as other vessels in the vicinity or animal life.
Simrad SC90 Installation Manual
Summary of Contents for SC90
Page 2: ......
Page 16: ...14 419050 B Simrad SC90 ...
Page 219: ...419050 B 217 Øverland UPC 3005 Dimensions Cable layout and interconnections ...
Page 223: ...419050 B 221 Øverland UPC 5000P Dimensions Cable layout and interconnections ...
Page 438: ...436 419050 B 427177 Transducer dock dimensions page 494 Simrad SC90 Installation Manual ...
Page 441: ...419050 B 439 Drawing file ...
Page 442: ...440 419050 B Simrad SC90 Installation Manual ...
Page 445: ...419050 B 443 Drawing file ...
Page 452: ...450 419050 B Simrad SC90 Installation Manual ...
Page 455: ...419050 B 453 Drawing file ...
Page 458: ...456 419050 B Simrad SC90 Installation Manual ...
Page 463: ...419050 B 461 Drawing file ...
Page 468: ...466 419050 B Simrad SC90 Installation Manual ...
Page 469: ...419050 B 467 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 471: ...419050 B 469 Drawing file ...
Page 473: ...419050 B 471 214043 Gate valve installation DN350 Drawing file ...
Page 475: ...419050 B 473 422915 Gate valve installation DN350 Drawing file ...
Page 477: ...419050 B 475 083045 Gate valve installation DN500 Drawing file ...
Page 479: ...419050 B 477 33414 Gate valve dimensions DN350 Drawing file ...
Page 480: ...478 419050 B Simrad SC90 Installation Manual ...
Page 481: ...419050 B 479 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 482: ...480 419050 B 33473 Gate valve dimensions DN350 Simrad SC90 Installation Manual ...
Page 483: ...419050 B 481 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 484: ...482 419050 B 33498 Gate valve dimensions DN500 Simrad SC90 Installation Manual ...
Page 485: ...419050 B 483 Drawing file ...
Page 487: ...419050 B 485 37357 Gate valve dimensions DN500 Drawing file ...
Page 488: ...486 419050 B Simrad SC90 Installation Manual ...
Page 489: ...419050 B 487 Related topics Installing the optional gate valve DN500 page 103 Drawing file ...
Page 491: ...419050 B 489 Drawing file ...
Page 494: ...492 419050 B Simrad SC90 Installation Manual ...
Page 495: ...419050 B 493 Related topics Installing the optional gate valve DN350 page 84 Drawing file ...
Page 497: ...419050 B 495 Drawing file ...
Page 542: ... 2018Kongsberg Maritime ISBN xxx ...
Page 543: ......
Page 544: ...Simrad SC90 Fish finding sonar Installation Manual ...